<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FAQs Archive - Stairhill</title>
	<atom:link href="https://www.stairhill.co.uk/faq-items/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.stairhill.co.uk/faq-items/</link>
	<description>Architecture &#38; Developments</description>
	<lastBuildDate>Tue, 05 Dec 2023 12:54:43 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Ventilation System Guidance</title>
		<link>https://www.stairhill.co.uk/faq-items/ventilation-system-guidance/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:43:19 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=661</guid>

					<description><![CDATA[<p>Column 1 Column 2 5-10 m³/hr.m² Intermittent extract fans with trickle vents to windows  3-5 m³/hr.m² Decentralised Mechanical ventilation system with trickle vents to windows.  &lt; 3 m³/hr.m² Full house mechanical ventilation system (Mechanical ventilation heat recovery system) </p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/ventilation-system-guidance/">Ventilation System Guidance</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap" style="max-width:1248px;margin-left: calc(-4% / 2 );margin-right: calc(-4% / 2 );"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column" style="--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="table-1" id="attg">
<table width="100%">
<thead>
<tr>
<th align="left">Column 1</th>
<th align="left">Column 2</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left"><span class="TextRun SCXW67741726 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW67741726 BCX9">5-10</span> <span class="NormalTextRun SCXW67741726 BCX9">m</span><span class="NormalTextRun SCXW67741726 BCX9">³</span><span class="NormalTextRun SCXW67741726 BCX9">/hr.m</span><span class="NormalTextRun SCXW67741726 BCX9">²</span></span></td>
<td align="left"><span class="TextRun SCXW187958170 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW187958170 BCX9">Intermittent extract fans with trickle vents to windows</span></span><span class="EOP SCXW187958170 BCX9" data-ccp-props="{"> </span></td>
</tr>
<tr>
<td align="left"><span class="NormalTextRun SCXW188787466 BCX9">3-5 </span><span class="NormalTextRun SCXW188787466 BCX9">m</span><span class="NormalTextRun SCXW188787466 BCX9">³</span><span class="NormalTextRun SCXW188787466 BCX9">/hr.m</span><span class="NormalTextRun SCXW188787466 BCX9">²</span></td>
<td align="left"><span class="TextRun SCXW80315911 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW80315911 BCX9">Decentralised Mechanical ventilation system with trickle vents to windows.</span></span><span class="EOP SCXW80315911 BCX9" data-ccp-props="{"> </span></td>
</tr>
<tr>
<td align="left"><span class="NormalTextRun SCXW34962818 BCX9">&lt; 3 </span><span class="NormalTextRun SCXW34962818 BCX9">m</span><span class="NormalTextRun SCXW34962818 BCX9">³</span><span class="NormalTextRun SCXW34962818 BCX9">/hr.m</span><span class="NormalTextRun SCXW34962818 BCX9">²</span></td>
<td align="left"><span class="TextRun SCXW41496238 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW41496238 BCX9">Full house mechanical ventilation system (Mechanical ventilation heat recovery system)</span></span><span class="EOP SCXW41496238 BCX9" data-ccp-props="{"> </span></td>
</tr>
</tbody>
</table>
</div>
</div></div></div></div>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/ventilation-system-guidance/">Ventilation System Guidance</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How are the results given and what do they mean?</title>
		<link>https://www.stairhill.co.uk/faq-items/how-are-the-results-given-and-what-do-they-mean/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:43:03 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=659</guid>

					<description><![CDATA[<p>The results of the air tightness test are given with a figure in m³/hr.m²  Good practice target is for a result anywhere between 5-7 m³/hr.m²  The result of the test can have an impact on the installed ventilation system and must be checked that the ventilation as installed is compatible with the air permeability result. </p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/how-are-the-results-given-and-what-do-they-mean/">How are the results given and what do they mean?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span data-contrast="auto">The results of the air tightness test are given with a figure in m³/hr.m²</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p><span data-contrast="auto">Good practice target is for a result anywhere between 5-7 m³/hr.m²</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p><span data-contrast="auto">The result of the test can have an impact on the installed ventilation system and must be checked that the ventilation as installed is compatible with the air permeability result.</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/how-are-the-results-given-and-what-do-they-mean/">How are the results given and what do they mean?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>When should I have an air tightness test carried out?</title>
		<link>https://www.stairhill.co.uk/faq-items/when-should-i-have-an-air-tightness-test-carried-out/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:42:31 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=657</guid>

					<description><![CDATA[<p>Air tightness tests should be carried out at completion stage prior to handover. The results from the air permeability test are used within SAP software to produce the final as built EPC.  Where a dwelling has been designed with a low air permeability target below 3 m³/hr.m² we would advise that a mid-build test is …</p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/when-should-i-have-an-air-tightness-test-carried-out/">When should I have an air tightness test carried out?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span data-contrast="auto">Air tightness tests should be carried out at completion stage prior to handover. The results from the air permeability test are used within SAP software to produce the final as built EPC.</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p><span data-contrast="auto">Where a dwelling has been designed with a low air permeability target below 3 m³/hr.m² we would advise that a mid-build test is carried out once the air barrier layer has been installed. This allows early identification of any potential leaks and allows them to be sealed at source. A final test is still required at completion.</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/when-should-i-have-an-air-tightness-test-carried-out/">When should I have an air tightness test carried out?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What do I need to do before an air tightness test?</title>
		<link>https://www.stairhill.co.uk/faq-items/what-do-i-need-to-do-before-an-air-tightness-test/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:38:41 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=652</guid>

					<description><![CDATA[<p>Know your design permeability value found in the SAP calculation and measured in m³/hr.m² All external walls, floors and roofs to be completely installed. All windows and doors should be fitted with draft proofing installed to all external doors where required. All fittings should be installed (including electrical) any ducts to external air should be …</p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/what-do-i-need-to-do-before-an-air-tightness-test/">What do I need to do before an air tightness test?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap" style="max-width:1248px;margin-left: calc(-4% / 2 );margin-right: calc(-4% / 2 );"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column" style="--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column"><ul style="--awb-size:22px;--awb-margin-top:0px;--awb-margin-right:0px;--awb-margin-bottom:0px;--awb-margin-left:0px;--awb-iconcolor:var(--awb-custom_color_2);--awb-line-height:37.4px;--awb-icon-width:37.4px;--awb-icon-height:37.4px;--awb-icon-margin:15.4px;--awb-content-margin:52.8px;" class="fusion-checklist fusion-checklist-1 fusion-checklist-default fusion-checklist-divider type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">Know your design permeability value found in the SAP calculation and measured in m³/hr.m²</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">All external walls, floors and roofs to be completely installed.</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">All windows and doors should be fitted with draft proofing installed to all external doors where required.</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">All fittings should be installed (including electrical) any ducts to external air should be sealed.</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">Plumbing work should be completed with all sanitary ware installed. All traps require to be filled with water. Bathrooms and kitchens are common places for leakage through poorly sealed drainage pipes often hidden by kitchen units or bathroom fixtures. Before fitting bath panels, boxing in or vanity units etc, pipework should be checked to ensure an airtight seal is in place around the pipework.</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">Doors to unheated garages, loft hatches, coomb access hatches etc should all be fitted with draught excluders.</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">Mains power is available within the dwelling</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">The house must have a minimum of one external door of standard dimensions not more than 2.5m tall or 1.1m wide</div></li></ul></div></div></div></div>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/what-do-i-need-to-do-before-an-air-tightness-test/">What do I need to do before an air tightness test?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Why is air tightness testing important?</title>
		<link>https://www.stairhill.co.uk/faq-items/why-is-air-tightness-testing-important/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:38:16 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=650</guid>

					<description><![CDATA[<p>Airtightness is important for avoiding heat loss as it means less uncontrolled air movement in and out of the building (cold drafts). Minimizing heat loss also means your heating and ventilation systems will work at their optimum efficiency, thereby reducing heating bills and energy wastage. </p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/why-is-air-tightness-testing-important/">Why is air tightness testing important?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="TextRun Highlight SCXW17402594 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW17402594 BCX9">Airtightness is important for </span></span><span class="TextRun SCXW17402594 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW17402594 BCX9">avoiding heat loss as it means less uncontrolled air movement in and out of the building</span><span class="NormalTextRun SCXW17402594 BCX9"> (cold drafts)</span></span><span class="TextRun Highlight SCXW17402594 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW17402594 BCX9">. </span><span class="NormalTextRun SCXW17402594 BCX9">Minimizing </span><span class="NormalTextRun SCXW17402594 BCX9">heat loss also means your heating </span><span class="NormalTextRun SCXW17402594 BCX9">and ventilation </span><span class="NormalTextRun SCXW17402594 BCX9">system</span><span class="NormalTextRun SCXW17402594 BCX9">s</span><span class="NormalTextRun SCXW17402594 BCX9"> will work </span><span class="NormalTextRun SCXW17402594 BCX9">at their </span><span class="NormalTextRun SCXW17402594 BCX9">optimum</span><span class="NormalTextRun SCXW17402594 BCX9"> efficiency</span><span class="NormalTextRun SCXW17402594 BCX9">, thereby reducing heating bills and energy wastage.</span><span class="NormalTextRun SCXW17402594 BCX9"> </span></span></p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/why-is-air-tightness-testing-important/">Why is air tightness testing important?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Do I need to have an air tightness test carried out?</title>
		<link>https://www.stairhill.co.uk/faq-items/do-i-need-to-have-an-air-tightness-test-carried-out/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:37:47 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=648</guid>

					<description><![CDATA[<p>All new homes in Scotland under current regulations - Domestic Technical Handbook (June 2023) require to have an air tightness test carried out in accordance with CIBSE TM23 </p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/do-i-need-to-have-an-air-tightness-test-carried-out/">Do I need to have an air tightness test carried out?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="TextRun SCXW218807470 BCX9" lang="EN-GB" xml:lang="EN-GB" data-contrast="auto"><span class="NormalTextRun SCXW218807470 BCX9">All new homes in Scotland under current</span><span class="NormalTextRun SCXW218807470 BCX9"> regulations &#8211;</span><span class="NormalTextRun SCXW218807470 BCX9"> Domestic Technical Handbook (June 2023) require </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW218807470 BCX9">to have</span><span class="NormalTextRun SCXW218807470 BCX9"> an air tightness test carried out </span><span class="NormalTextRun SCXW218807470 BCX9">in accordance with</span><span class="NormalTextRun SCXW218807470 BCX9"> CIBSE TM23</span></span><span class="EOP SCXW218807470 BCX9" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}"> </span></p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/do-i-need-to-have-an-air-tightness-test-carried-out/">Do I need to have an air tightness test carried out?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What is Air Tightness Testing?</title>
		<link>https://www.stairhill.co.uk/faq-items/what-is-air-tightness-testing/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 Dec 2023 12:37:28 +0000</pubDate>
				<guid isPermaLink="false">https://dev.stairhill.co.uk/?post_type=avada_faq&#038;p=646</guid>

					<description><![CDATA[<p>Air tightness testing sometimes referred to as air permeability testing, air leakage testing and air pressure testing measures the amount of uncontrolled air escaping through the external fabric of the building envelope.   The air tightness test determines the amount of air leakage in cubic metres per square metre of internal surface area of the building. …</p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/what-is-air-tightness-testing/">What is Air Tightness Testing?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span data-contrast="auto">Air tightness testing sometimes referred to as air permeability testing, air leakage testing and air pressure testing measures the amount of uncontrolled air escaping through the external fabric of the building envelope. </span><span data-ccp-props="{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<p><span data-contrast="auto">The air tightness test determines the amount of air leakage in cubic metres per square metre of internal surface area of the building. Or, to put it simply, air tightness testing measures the amount of air that escapes (drafts) through the gaps or building fabrics. Ideally, having an airtight building means that less energy will be wasted through the leakage of heated air. </span><span data-ccp-props="{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<p><span data-contrast="auto">All new homes in Scotland require to have an air test carried out in accordance with CIBSE TM23</span></p>
<p>The post <a href="https://www.stairhill.co.uk/faq-items/what-is-air-tightness-testing/">What is Air Tightness Testing?</a> appeared first on <a href="https://www.stairhill.co.uk">Stairhill</a>.</p>
]]></content:encoded>
					
		
		